<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-22 06-18-49
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.40 MHz 5/5, 74 dBuV BASSO
Pilot RDS Phase Difference
6.6 kHz 3.0 kHz 53 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 19020 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,02 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" BASSO " 62AB 0 (No PTY) 1 0 1 1 --:--
RT
-
AF EON
101.4, 101.6 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/03/22 6.17.45 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000
FM Scope MAX: 5,6 dBr MIN: 3,9 dBr AVE: 5,02 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2025/03/22 6.17.45) 06.04 06.06 06.08 06.10 06.12 06.14 06.16 0 2 4 6 Pm [dBr]